{"product_id":"safety-shower-eyewash-test-services","title":"Safety Shower \u0026 Eyewash Test Services","description":"\u003ch1 data-end=\"464\" data-start=\"130\"\u003e\u003cstrong\u003eSafety Shower \u0026amp; Eyewash Test Services\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-end=\"464\" data-start=\"130\"\u003eEmergency drenching and flushing equipment must \u003cstrong data-end=\"210\" data-start=\"178\"\u003ework instantly and correctly\u003c\/strong\u003e when an exposure occurs. SPILLDOC’s \u003cstrong data-end=\"288\" data-start=\"247\"\u003eSafety Shower \u0026amp; Eyewash Test Services\u003c\/strong\u003e verify that your stations perform to \u003cstrong data-end=\"346\" data-start=\"326\"\u003eANSI\/ISEA Z358.1\u003c\/strong\u003e requirements and meet expectations within \u003cstrong data-end=\"408\" data-start=\"389\"\u003eSingapore’s WSH\u003c\/strong\u003e environment for emergency preparedness and maintenance.\u003c\/p\u003e\n\u003cp data-end=\"602\" data-start=\"466\"\u003eWe conduct structured testing, measurement, documentation, and tagging to ensure every unit on your site is \u003cstrong data-end=\"601\" data-start=\"574\"\u003eready for immediate use\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"607\" data-start=\"604\"\u003e\n\u003ch3 data-end=\"656\" data-start=\"609\"\u003eWhy Testing Matters in Singapore Workplaces\u003c\/h3\u003e\n\u003cp data-end=\"925\" data-start=\"658\"\u003eUnder Singapore’s Workplace Safety and Health (WSH) duties, employers must ensure emergency equipment is \u003cstrong data-end=\"805\" data-start=\"763\"\u003efunctional, accessible, and maintained\u003c\/strong\u003e. In chemical handling areas, laboratories, workshops, and process plants, non-performing showers\/eyewashes can lead to:\u003c\/p\u003e\n\u003cul data-end=\"1079\" data-start=\"926\"\u003e\n\u003cli data-end=\"967\" data-start=\"926\"\u003e\n\u003cp data-end=\"967\" data-start=\"928\"\u003eSerious injury during chemical exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1011\" data-start=\"968\"\u003e\n\u003cp data-end=\"1011\" data-start=\"970\"\u003eNon-compliance observations during audits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1079\" data-start=\"1012\"\u003e\n\u003cp data-end=\"1079\" data-start=\"1014\"\u003eEquipment failure due to poor maintenance or water quality issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1187\" data-start=\"1081\"\u003eSPILLDOC testing aligns your equipment condition with \u003cstrong data-end=\"1164\" data-start=\"1135\"\u003eANSI performance criteria\u003c\/strong\u003e and good WSH practice.\u003c\/p\u003e\n\u003chr data-end=\"1192\" data-start=\"1189\"\u003e\n\u003ch2 data-end=\"1246\" data-start=\"1194\"\u003eWhat SPILLDOC Tests (Aligned to ANSI\/ISEA Z358.1)\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2422\" data-start=\"1248\"\u003e\n\u003cthead data-end=\"1322\" data-start=\"1248\"\u003e\n\u003ctr data-end=\"1322\" data-start=\"1248\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1260\" data-start=\"1248\"\u003eTest Area\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1289\" data-start=\"1260\"\u003eANSI Requirement (Summary)\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1322\" data-start=\"1289\"\u003eWhat SPILLDOC Verifies Onsite\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2422\" data-start=\"1337\"\u003e\n\u003ctr data-end=\"1463\" data-start=\"1337\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1368\" data-start=\"1337\"\u003e\u003cstrong data-end=\"1367\" data-start=\"1339\"\u003eLocation \u0026amp; Accessibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1417\" data-start=\"1368\" data-col-size=\"md\"\u003eReachable within 10 seconds, unobstructed path\u003c\/td\u003e\n\u003ctd data-end=\"1463\" data-start=\"1417\" data-col-size=\"md\"\u003eTravel path, signage visibility, clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1578\" data-start=\"1464\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1487\" data-start=\"1464\"\u003e\u003cstrong data-end=\"1486\" data-start=\"1466\"\u003eActivation Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1533\" data-start=\"1487\" data-col-size=\"md\"\u003eOne-second activation, hands-free stay open\u003c\/td\u003e\n\u003ctd data-end=\"1578\" data-start=\"1533\" data-col-size=\"md\"\u003eValve operation, pull rod\/plate condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1676\" data-start=\"1579\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1602\" data-start=\"1579\"\u003e\u003cstrong data-end=\"1601\" data-start=\"1581\"\u003eShower Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1632\" data-start=\"1602\" data-col-size=\"md\"\u003e≥ 75.7 L\/min for 15 minutes\u003c\/td\u003e\n\u003ctd data-end=\"1676\" data-start=\"1632\" data-col-size=\"md\"\u003eMeasured flow using calibrated container\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1775\" data-start=\"1677\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1701\" data-start=\"1677\"\u003e\u003cstrong data-end=\"1700\" data-start=\"1679\"\u003eEyewash Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1730\" data-start=\"1701\" data-col-size=\"md\"\u003e≥ 1.5 L\/min for 15 minutes\u003c\/td\u003e\n\u003ctd data-end=\"1775\" data-start=\"1730\" data-col-size=\"md\"\u003eDual stream pattern, height and alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1864\" data-start=\"1776\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1796\" data-start=\"1776\"\u003e\u003cstrong data-end=\"1795\" data-start=\"1778\"\u003eSpray Pattern\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1823\" data-start=\"1796\" data-col-size=\"md\"\u003eProper flushing coverage\u003c\/td\u003e\n\u003ctd data-end=\"1864\" data-start=\"1823\" data-col-size=\"md\"\u003eSymmetry, steady streams, no blockage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1946\" data-start=\"1865\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1889\" data-start=\"1865\"\u003e\u003cstrong data-end=\"1888\" data-start=\"1867\"\u003eWater Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1907\" data-start=\"1889\" data-col-size=\"md\"\u003eTepid (16–38°C)\u003c\/td\u003e\n\u003ctd data-end=\"1946\" data-start=\"1907\" data-col-size=\"md\"\u003eTemperature measurement during flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2045\" data-start=\"1947\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1973\" data-start=\"1947\"\u003e\u003cstrong data-end=\"1972\" data-start=\"1949\"\u003eDuration Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2003\" data-start=\"1973\" data-col-size=\"md\"\u003eContinuous 15-minute supply\u003c\/td\u003e\n\u003ctd data-end=\"2045\" data-start=\"2003\" data-col-size=\"md\"\u003ePressure stability and supply adequacy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2149\" data-start=\"2046\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2076\" data-start=\"2046\"\u003e\u003cstrong data-end=\"2075\" data-start=\"2048\"\u003eWeekly Activation Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2108\" data-start=\"2076\" data-col-size=\"md\"\u003ePrevent stagnation \u0026amp; sediment\u003c\/td\u003e\n\u003ctd data-end=\"2149\" data-start=\"2108\" data-col-size=\"md\"\u003eEvidence of routine flushing practice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2253\" data-start=\"2150\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2175\" data-start=\"2150\"\u003e\u003cstrong data-end=\"2174\" data-start=\"2152\"\u003ePhysical Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2209\" data-start=\"2175\" data-col-size=\"md\"\u003eCorrosion, leaks, damaged parts\u003c\/td\u003e\n\u003ctd data-end=\"2253\" data-start=\"2209\" data-col-size=\"md\"\u003ePipework, heads, valves, drain condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2339\" data-start=\"2254\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2281\" data-start=\"2254\"\u003e\u003cstrong data-end=\"2280\" data-start=\"2256\"\u003eSignage \u0026amp; Visibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2304\" data-start=\"2281\" data-col-size=\"md\"\u003eClear identification\u003c\/td\u003e\n\u003ctd data-end=\"2339\" data-start=\"2304\" data-col-size=\"md\"\u003eANSI-compliant signage presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2422\" data-start=\"2340\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2365\" data-start=\"2340\"\u003e\u003cstrong data-end=\"2364\" data-start=\"2342\"\u003eInspection Tagging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2384\" data-start=\"2365\" data-col-size=\"md\"\u003eRecord of checks\u003c\/td\u003e\n\u003ctd data-end=\"2422\" data-start=\"2384\" data-col-size=\"md\"\u003eTagging, checklist, service record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2427\" data-start=\"2424\"\u003e\n\u003ch2 data-end=\"2449\" data-start=\"2429\"\u003eOur Service Scope\u003c\/h2\u003e\n\u003cul data-end=\"2858\" data-start=\"2451\"\u003e\n\u003cli data-end=\"2519\" data-start=\"2451\"\u003e\n\u003cp data-end=\"2519\" data-start=\"2453\"\u003eFunctional flow testing of \u003cstrong data-end=\"2519\" data-start=\"2480\"\u003esafety showers and eyewash stations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2582\" data-start=\"2520\"\u003e\n\u003cp data-end=\"2582\" data-start=\"2522\"\u003eMeasurement of \u003cstrong data-end=\"2582\" data-start=\"2537\"\u003eflow rate, spray pattern, and temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2646\" data-start=\"2583\"\u003e\n\u003cp data-end=\"2646\" data-start=\"2585\"\u003eInspection of valves, pipework, shower heads, eyewash nozzles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2714\" data-start=\"2647\"\u003e\n\u003cp data-end=\"2714\" data-start=\"2649\"\u003eIdentification of obstructions, corrosion, and poor accessibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2755\" data-start=\"2715\"\u003e\n\u003cp data-end=\"2755\" data-start=\"2717\"\u003eVerification of signage and visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2805\" data-start=\"2756\"\u003e\n\u003cp data-end=\"2805\" data-start=\"2758\"\u003eInspection tagging and service checklist report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2858\" data-start=\"2806\"\u003e\n\u003cp data-end=\"2858\" data-start=\"2808\"\u003eRecommendations for rectification if non-compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2863\" data-start=\"2860\"\u003e\n\u003ch2 data-end=\"2899\" data-start=\"2865\"\u003eSuitable for These Environments\u003c\/h2\u003e\n\u003cul data-end=\"3136\" data-start=\"2901\"\u003e\n\u003cli data-end=\"2936\" data-start=\"2901\"\u003e\n\u003cp data-end=\"2936\" data-start=\"2903\"\u003eChemical storage and dosing areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2975\" data-start=\"2937\"\u003e\n\u003cp data-end=\"2975\" data-start=\"2939\"\u003eLaboratories and research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3010\" data-start=\"2976\"\u003e\n\u003cp data-end=\"3010\" data-start=\"2978\"\u003eManufacturing and process plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3053\" data-start=\"3011\"\u003e\n\u003cp data-end=\"3053\" data-start=\"3013\"\u003eWarehouses handling hazardous substances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3100\" data-start=\"3054\"\u003e\n\u003cp data-end=\"3100\" data-start=\"3056\"\u003eMarine, oil \u0026amp; gas, and maintenance workshops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3136\" data-start=\"3101\"\u003e\n\u003cp data-end=\"3136\" data-start=\"3103\"\u003eConstruction and industrial sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3141\" data-start=\"3138\"\u003e\n\u003ch2 data-end=\"3181\" data-start=\"3143\"\u003eWhat You Receive After Each Service\u003c\/h2\u003e\n\u003cul data-end=\"3424\" data-start=\"3183\"\u003e\n\u003cli data-end=\"3224\" data-start=\"3183\"\u003e\n\u003cp data-end=\"3224\" data-start=\"3185\"\u003eCompleted inspection checklist per unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3270\" data-start=\"3225\"\u003e\n\u003cp data-end=\"3270\" data-start=\"3227\"\u003eFlow rate and temperature readings recorded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3309\" data-start=\"3271\"\u003e\n\u003cp data-end=\"3309\" data-start=\"3273\"\u003eEquipment status tag on each station\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3360\" data-start=\"3310\"\u003e\n\u003cp data-end=\"3360\" data-start=\"3312\"\u003eSummary report with findings and recommendations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3424\" data-start=\"3361\"\u003e\n\u003cp data-end=\"3424\" data-start=\"3363\"\u003eService record for WSH audit and internal compliance tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3429\" data-start=\"3426\"\u003e\n\u003ch2 data-end=\"3479\" data-start=\"3431\"\u003eRecommended Testing Frequency (Good Practice)\u003c\/h2\u003e\n\u003cul data-end=\"3671\" data-start=\"3481\"\u003e\n\u003cli data-end=\"3533\" data-start=\"3481\"\u003e\n\u003cp data-end=\"3533\" data-start=\"3483\"\u003e\u003cstrong data-end=\"3494\" data-start=\"3483\"\u003eWeekly:\u003c\/strong\u003e Internal activation flush by site team\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3606\" data-start=\"3534\"\u003e\n\u003cp data-end=\"3606\" data-start=\"3536\"\u003e\u003cstrong data-end=\"3562\" data-start=\"3536\"\u003eQuarterly \/ Bi-Annual:\u003c\/strong\u003e Professional functional testing by SPILLDOC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3671\" data-start=\"3607\"\u003e\n\u003cp data-end=\"3671\" data-start=\"3609\"\u003e\u003cstrong data-end=\"3651\" data-start=\"3609\"\u003eAfter plumbing works or modifications:\u003c\/strong\u003e Re-testing required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3676\" data-start=\"3673\"\u003e\n\u003ch2 data-end=\"3716\" data-start=\"3678\"\u003eKeep Your Emergency Equipment Ready\u003c\/h2\u003e\n\u003cp data-end=\"3902\" data-start=\"3718\"\u003eIn an exposure incident, there is no time to troubleshoot. SPILLDOC ensures your \u003cstrong data-end=\"3835\" data-start=\"3799\"\u003eSafety Shower \u0026amp; Eyewash Stations\u003c\/strong\u003e are fully functional, compliant, and ready to protect your people.\u003c\/p\u003e\n\u003cblockquote data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"4050\" data-start=\"3904\"\u003e\n\u003cp data-is-last-node=\"\" data-end=\"4050\" data-start=\"3906\"\u003eSchedule your \u003cstrong data-end=\"3972\" data-start=\"3920\"\u003eANSI Z358.1 Safety Shower \u0026amp; Eyewash Test Service\u003c\/strong\u003e with SPILLDOC for dependable emergency readiness in your Singapore workplace.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"SPILLDOC","offers":[{"title":"Default Title","offer_id":46532978704559,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true}],"url":"https:\/\/www.spilldoc.sg\/products\/safety-shower-eyewash-test-services","provider":"Spilldoc Singapore","version":"1.0","type":"link"}